Siemens Advia Chemistry XPT System
Product Code: 10723034
Manufacturer: Siemens Healthineers
The frugal way to reduce turnaround times.
The Siemens Advia Chemistry XPT is the smartest replacement for your older Advia 2400 or similar chemistry analyzer.
You will:
- Reduce turnaround times by 40-50%
- Increase throughput by 30-35%
- Reduce overtime costs and improve staff utilization
Get 70+ more annual hours of runtime
Hospital Clinic de Barcelona, a public university hospital in Barcelona, Spain, replaced an older Advia analyzer with the Advia Chemistry XPT and gained 70 hours of annual runtime.
Dr. Jose Luis Bedini,
Head of Biomedical Diagnostic
Center Core Laboratory, Hospital Clinic de Barcelona.
Your lab can generate the same results at a manageable cost within the month.
Significantly cut your cost per test
The cost of each test in the lab includes QC material, calibration material, reagents, and other consumables.
Some labs have reduced those costs by 50-60% by replacing old Advia systems with Advia Chemistry XPT and Advia Centaur XPT systems.
Your Advia XPT pays for itself via reduced costs and improved throughput in about 2 years.
Click here and get your quote in 90 minutes
Save time compared to your Advia XP analyzers too!
Your best operators should spend their time on science, not service.
You can do this with the newest analyzers, at a huge cost.
Or you can do it frugally, with an Advia XPT that’s ready to ship this week.
Use your old Advia to pay for part of your new Advia XPT
Finance your investment keep budget free for emergencies
Contact a member of our team to learn more
An easy way to reduce your mental burden
Nation-wide, onsite service is available for your Advia Chemistry XPT. We can give you:
- Customized on-site annual service contracts.
- Professional installation.
- Familiarization training following installation.
- Time and material service visits, if you choose not to enter a service contract.
Live in a world with less stress
Block Scientific has served clinical labs across the United States and around the world for more than 40 years. We know the stress you're under every day and we want to help.
Your Siemens Advia Chemistry XPT is ready to ship when you need it. And it always arrives as expected.
We also offer a 30-day satisfaction guarantee. So try it. There’s no risk.
We’ll send you a quote within 90 minutes today
Anemia
Active B12
Ferritin
Folate
RBC Folate
Vitamin B12
Autoimmune
Anti-CCP
Bone Metabolism
Intact PTH
Vitamin D Total
Cardiac
BNP
CKMB
High-Sensitivity Troponin I (TNIH)
Myoglobin
TnI-Ultra™
Diabetes
C-Peptide
Insulin
Liver Disease – NASH
ELF™ [Enhanced Liver Fibrosis]
Hepatitis
Anti-HBs2
HAV IgM
HAV Total
HBc IgM
HBc Total
HBe Ag
HBs Ag Confirmatory
HBs AgII
HCV***
HIV
HIV 1/O/2 Enhanced (EHIV)§
HIV Combo§
Immunosuppressant Drugs
Cyclosporine
Everolimus**
Tacrolimus**
Inflammation
IgE, Total
Metabolic
Cortisol
Homocysteine
Oncology
AFP
BR 27.29
CA 125II‡
CA 15-3
CA 19-9
Calcitonin
CEA
Complexed PSA
PSA
Serum HER-2/neu
Reproductive Endocrinology
AFP
Anti-Müllerian Hormone**
DHEAS
Enhanced Estradiol
Free βhCG‡‡
FSH
hCG
LH
PAPP-A‡‡
PlGF**
Progesterone
Prolactin
sFLT-1**
SHBG
Testosterone II
Special ID
EBV-EBNA IgG**
EBV-VCA IgG**
EBV-VCA IgM**
Syphilis
Zika IgM††
Therapeutic Drug Monitoring (TDM)
Carbamazepine
Digitoxin
Digoxin
Gentamicin
Phenobarbital
Phenytoin
Theophylline
Valproic Acid
Vancomycin
Thyroid
Anti-TG
Anti-TPO
Free T3
Free T4
T Uptake
Total T3
Total T4
TSH3-Ultra
TSH
ToRCH
CMV IgG
CMV IgM**
Herpes-1 IgG
Herpes-2 IgG
Rubella IgG
Rubella IgM
Toxoplasma IgG
Toxoplasma IgM
Technical Specifications
Product Specifications | |
---|---|
System Description | Random-access immunoassay system |
Test Throughput | Up to 240 tests per hour |
Time to First Result | 18 minutes; results every 15 seconds thereafter, assay dependent |
Assays Onboard | 30 assays |
Disease-State Assay Groups | Allergy, Anemia/Iron Metabolism, Bone Metabolism, Cardiac, Diabetes, Hepatitis, Immunosuppressant Drugs, Metabolic, Oncology, Reproductive Endocrinology, Special ID, Therapeutic Drug Monitoring (TDM), Thyroid, ToRCH |
Continuous Operation | Loading/unloading of samples and consumables at any time without interrupting system operation. Includes sample racks, STATs, reagent packs, ancillary reagent packs, reaction cuvettes, sample pipette tips, calibrators, controls, wash fluids, water, and waste. |
Sample Handling | |
Sample Tubes | 3 mL, 5 mL, 7 mL, and 10 mL tubes; 1 mL and 2 mL sample cups; microcontainer tubes |
Sample Input | Universal 5-position rack holds multiple tube types; 180 samples fully loaded; no-pause loading and unloading |
Validated Sample Types | Serum, plasma, urine (assay-dependent) |
Sample Volume per Test | 10–200 μL, assay-dependent |
Sample Integrity Control | Pressure transducer technology with clot detection, flagging, and management; short-sample detection |
STAT Handling | Dedicated STAT port accepts samples any time; STAT samples are processed with priority |
Auto-repeat | User-definable |
Sample Dilution | Automatic dilution varies by assay, up to 1:2500 |
Auto-reflex Testing | Automatic ability to perform additional tests based on results of first test |
Sample Pipette Tips | 840 disposable sample tip capacity |
Sample Carryover Prevention | Disposable pipette tips ensure zero sample carryover |
Bar Codes | |
Sample Bar Codes | Up to 20 digits; Interleaved 2 of 5; Code 39, Code 128, Codabar; A, B, and special characters (.-+/*$%) |
Reaction Area | |
Reaction Cuvettes | Capacity of 1000 optical-grade plastic cuvettes |
Reaction Bath | Air bath, 37°C |
Assay Result Calculations | SMART algorithm software repeats and confirms reactive testing; results available as completed |
Assay Technology | Chemiluminescence using Advanced Acridinium Ester |
Reagent Handling | |
Reagent Tray | 30-position reagent tray refrigerated between 4 and 10°C (39–50°F) |
Reagent Capacity Onboard | 30 assays |
Reagent Containers | ADVIA Centaur® ReadyPack® (various pack sizes available) |
Reagent Integrity Control | Bar-code reagent identification, automatic inventory tracking and flagging, calibration valid tracking and flagging, reagent onboard stability tracking and flagging, reagent expired/reagent low flagging |
Onboard Stability | 28 days (average) |
Reagent Mixing | ADVIA Centaur ReadyPacks automatically rocked onboard |
Ancillary Reagents | 25-position ancillary reagent tray cooled 4–8°C (39–46°F) |
Calibration/QC | |
Auto-calibration/Auto-QC | Available automatic QC ordering by test, control, date, and time |
QC Data | Advanced QC package includes Levey-Jennings plots and Westgard rules |
User Interface/Data Management | |
Monitor | 22-inch diagonal high-resolution LCD touchscreen with adjustable height |
Operating System | Microsoft® Windows® 7 |
System Documentation | Operator manual, quickstart guide, and context-sensitive online help |
Data Storage | 1,000,000 test/QC results; 500,000 can be historical; can archive to removable media |
Onboard Maintenance Logs | Yes |
Host Interface | RS232C bidirectional and host query; Ethernet connection available |
Host Query | Yes |
Remote Access & Service | 1000Base-T Ethernet port for remote access and modem for Siemens Remote Service |
Removable Media | |
Removable Media | CD, DVD, or USB |
General Specifications | |
Power Requirements | 200-240 V at 50/60 Hz; 1.2 kW maximum |
Maximum Water Consumption | 2.5 liters (0.6 gallons) per hour |
Drain Requirements | Minimum of 2.5 liters (0.6 gallons) per hour |
Dimensions | With monitor: 167 (h) x 196 (w) x 104 (d) cm; 66 (h) x 77 (w) x 41 (d) in. Without monitor: 133 (h) x 196 (w) x 104 (d) cm; 52 (h) x 77 (w) x 41 (d) in. |
Weight | 585 kg (1289 lb) |
Compliance | Complies with international environmental, health, and safety standards |
Noise Emission | 65 dB maximum |
Processing Heat Output | 5100 BTU/hour |
Ambient Temperature | 18–30°C (64–86°F) |
Ambient Humidity | 20–80% noncondensing |
Floor Load-Bearing Requirement | 412 kg/m2 (84 lb/ft2) |